Service — Outdoor & garden power

Garden power that survives a Surrey winter.

Garden offices, hot tubs, pond pumps and festoon lighting all want the same thing underneath: armoured cable, proper RCD protection, and glands done right. Outdoor electrics fail at the shortcuts — so we don’t take them.

Garden sockets from £340 · garden office supply from £780, inc. VAT

An English garden at dusk with path lights and festoon lighting, armoured cable clipped along a brick wall

What’s included

  • Steel-wire armoured (SWA) cable, buried at proper depth with warning tape
  • RCD protection on every outdoor circuit — non-negotiable
  • IP-rated sockets and switches that still work after five Novembers
  • A small sub-board in garden buildings so a trip out there stays out there
  • Reinstated lawn or borders where the trench runs — we dig tidy
  • Certification and Part P notification where the job requires it

Certification issued: EIC or Minor Works Certificate; Part P notified where required


How it goes

  1. 01

    Walk the route

    From the consumer unit to wherever the power is going — we measure the run and check the board has capacity.

    30–45 minutes

  2. 02

    Trench and cable

    SWA laid at depth, taped and sanded. You can dig the trench yourself to save money — we’ll tell you exactly where and how deep.

    ½–1 day

  3. 03

    Connect and fit out

    Glanding, sub-board, sockets and lighting in the building or on the terrace.

    ½–1 day

  4. 04

    Test and certify

    Tested end to end, certificated, and notified to Building Control where the job needs it.

    Certificate within 48 hours

What moves the price

Factor Why it matters
Run length Garden office supplies start at £780 for runs to 10m; beyond that it’s £16 a metre for cable and burying.
What’s at the end A socket is simple; a hot tub circuit (£520) or an office with heating and a kiln-sized load needs bigger cable and its own protection.
The digging Lawn is easy, patio isn’t. Dig your own trench to our spec and the price drops accordingly.
Points and lighting Sockets and light positions are £85 a point after the £340 base — the scheme scales predictably.

Questions we actually get asked

Can’t I just run an extension lead to the shed?

For a mower on a dry afternoon, fine. As a permanent supply, no — leads through windows fail every test of safety and every insurance claim. A proper buried supply is a one-off cost that ends the question.

How deep does the cable go?

Deep enough that a spade won’t find it — typically 450mm under lawns and 600mm under driveways, with marker tape above. That’s the standard, and it’s where we put it.

Does a garden office need its own fusebox?

Its own small sub-board, yes — so sockets, lighting and heating out there are protected locally and a fault doesn’t take out the house. It also makes future additions cheap.

Can you power a hot tub?

Yes — £520 for a typical dedicated circuit with rotary isolator. Tell us the model before we quote; their demands vary more than the brochures admit.

Do garden electrics need Building Control?

New outdoor circuits are notifiable under Part P. We’re registered to self-certify, so the notification is handled by us and included in the price.